Skip to content
In My Home Products

How to Choose an Air Purifier: CADR, HEPA and Room Size Explained

What CADR means, how to size a purifier to your room, what True HEPA really is, and the ozone, noise and filter-cost traps to avoid before you buy.

By The In My Home Products Editorial Team

Published · 6 min read

SaveFacebookX

We may earn a commission when you buy through links on this page. As an Amazon Associate, we earn from qualifying purchases. How we make money.

Levoit Core 300-P, Winix 5520 and Blueair Blue Pure 311i+ Max air purifiers
Image: Levoit, Winix, Blueair

The short answer

  1. 1Size by smoke CADR: AHAM recommends at least two-thirds of the room's floor area, so a 300 sq ft room needs a smoke CADR of about 200. Size up for ceilings above 8 feet.
  2. 2For particles, look for a True HEPA filter (at least 99.97% at 0.3 microns). For odors and gases, you need a substantial activated carbon filter. CADR doesn't measure gases.
  3. 3Avoid anything that intentionally makes ozone, budget for filters, and remember ENERGY STAR measures efficiency, not cleaning power.

Air purifier boxes are full of big numbers: "covers 1,700 sq ft," "removes 99.99% of particles," "5-in-1 filtration." Most of them don't help you compare. The good news is that three things decide whether a purifier will work in your room: its smoke CADR, its filter and whether it fits your room size. Everything below is drawn from the EPA's guide to air cleaners in the home and from AHAM, the trade group that runs the CADR rating program.

If you just want the number for your room, skip ahead to our air purifier room size calculator.

CADR: the one number that matters most

CADR, the clean air delivery rate, tells you how much filtered air a purifier delivers per minute. The EPA explains that it's rated for three pollutants that stand in for different particle sizes: tobacco smoke (small), dust (medium) and pollen (large). It's typically measured at the highest fan speed.

For most homes, the smoke CADR is the one to read. Small particles are the hardest to catch and include smoke and much of what bothers allergy and asthma sufferers. A purifier that scores well on smoke usually does fine on dust and pollen too. (Buying for allergies? Pair the purifier with the free fixes in our allergies at home plan.)

Two cautions:

  • CADR covers particles only. It doesn't measure gases or odors.
  • Some brands publish one number. Levoit, for example, gives the Core 300-P a single 143 CFM CADR without naming the pollutant. In that case, lean on the room size rating instead.

How to size an air purifier for your room

The two-thirds rule

AHAM recommends a smoke CADR of at least two-thirds of your room's floor area. The EPA's sizing chart works out the same way:

Room sizeMinimum smoke CADR
100 sq ft65 CFM
200 sq ft130 CFM
300 sq ft195 CFM
400 sq ft260 CFM
500 sq ft325 CFM
600 sq ft390 CFM

For wildfire smoke, AHAM recommends going further: a smoke CADR equal to the room's square footage.

Adjust for ceilings and open plans

That chart assumes an 8-foot ceiling. With 10-foot or vaulted ceilings, there's more air to clean, so buy more CADR. In an open floor plan, the EPA suggests sizing for the whole connected space or using multiple units.

Air changes per hour

Air changes per hour (ACH) is how many times per hour the purifier can filter the room's full volume. Here's the formula:

ACH = smoke CADR × 60 ÷ (floor area × ceiling height)

A 233 CFM purifier in a 300 sq ft room with 8-foot ceilings delivers 233 × 60 ÷ 2,400, or about 5.8 ACH. To work backward, minimum CADR = target ACH × room volume ÷ 60.

AHAM's suggested room sizes are based on 4.8 ACH, which works out to smoke CADR × 1.55. The same AHAM paper notes that the CDC recommends at least 5 total air changes per hour in occupied spaces.

Ignore "1 ACH" coverage claims

Those huge coverage numbers, like 1,748 sq ft or "3,235 sq ft in one hour," are based on a single air change per hour. That's far slower than the 4.8 ACH behind AHAM room sizes. Compare the 4.8 ACH figure. If a brand lists its AHAM Verified room size, even better: among the models we track, the Winix 5520 states AHAM Verified status for 392 sq ft on its product page. You can check any model in AHAM's directory of verified air cleaners.

Filters: HEPA, carbon and the rest

What True HEPA means

The EPA cites the Department of Energy definition: a HEPA filter can theoretically remove at least 99.97% of airborne particles 0.3 microns in size. That size is the hardest to catch. Larger and smaller particles are trapped more efficiently.

Labels vary. "HEPA-type" or "HEPA-like" has no standard meaning. Some strong purifiers don't claim True HEPA at all. Blueair's HEPASilent filters, for example, combine electrostatic charging with mechanical filtration. They post high CADR numbers, but they aren't a mechanical True HEPA filter. Judge any purifier by its CADR first, then by its filter claims.

Activated carbon for odors and gases

To remove odors and gases, the EPA says to choose a purifier with an activated carbon or other sorbent filter, and that more material works better. A thin carbon-coated sheet does little for cooking smells or smoke odors. Pellet-style carbon, like the Winix 5520's, holds more. There's no widely used rating system for gas removal, so you can't compare carbon filters by number. If pet odors are the main problem, see our best air purifiers for pets.

Plasma, PCO and UV

The EPA notes that research hasn't shown that plasma, photocatalytic oxidation (PCO) or UV features effectively remove gases in portable home units. Don't pay extra for them.

Ozone, ionizers and certifications

The EPA advises avoiding air cleaners that intentionally produce ozone, a lung irritant, and states that no federal agency has approved ozone generators for occupied spaces. It also notes that electrostatic precipitators, ionizers, uncoated UV lamps and plasma air cleaners may emit some ozone.

Many popular purifiers include an ionizing feature. The Coway Airmega Mighty has a bipolar ionizer stage, and the Winix 5520 has PlasmaWave. Winix publishes a very low ozone figure for the 5520 and says PlasmaWave can be switched off. For any model, check the manual for how to disable the feature.

California regulates ozone from indoor air cleaners. The California Air Resources Board keeps a list of certified devices, and the EPA points to CARB and AHAM lists of products tested for little or no ozone. Filter-only purifiers sidestep the issue; we weigh an ionizer model against a filter-only one in Coway vs Levoit.

Noise: plan for the speed you'll use

Noise depends on fan speed. The EPA suggests choosing a purifier with a low published noise rating if noise would keep you from running it. About 50 dB is roughly a modern refrigerator. Most purifiers we track publish low speeds of 22 to 24 dB and top speeds around 50 to 54.5 dB, as published by their makers.

AHAM adds a useful point: the right size is the best noise control. An undersized purifier has to run on high. One with extra CADR can clean the room on a quiet setting. That's why we recommend a bedroom unit rated for more than your room.

Filter costs: the price you pay every year

The EPA notes that every filter needs regular replacement, because a dirty or overloaded filter doesn't work well. Before you buy, look up the replacement filter and its interval. As rough tiers:

  • Lower yearly cost: small purifiers with inexpensive filters, like the Levoit Core 300-P (every 6 to 8 months).
  • Moderate: mid-size models with one yearly set or 9-month filters, like the Winix 5520 and Blueair 311i+ Max.
  • Higher: large-room purifiers with bigger filters, like the Blueair 211i Max. See our best air purifiers for large rooms.

Over three to five years, filters can cost as much as the purifier. Check today's price on filters, not just on the unit.

ENERGY STAR: efficiency only

An ENERGY STAR label means the purifier meets EPA energy-efficiency guidelines. The EPA is clear that it doesn't speak to air-cleaning effectiveness. It's worth having for a purifier that runs around the clock, but compare CADR first.

Common mistakes

  • Buying for the box's coverage number instead of the 4.8 ACH room size.
  • Undersizing, then running the purifier on high and finding it too loud.
  • Expecting a purifier to fix humidity or mold. Purifiers don't remove moisture. If a basement feels damp, start with our dehumidifier size calculator.
  • Ignoring filter cost and availability. Confirm genuine filters are easy to buy.
  • Placing it in a corner behind furniture. Give it open space so air can flow in and out.

Price tiers and where to start

Most good room purifiers sit in the $$ to $$$ list-price tiers. Budget models cover small bedrooms. Mid-tier models cover living rooms and add sensors and auto mode. Higher-tier units add capacity for open plans or app control.

Levoit Core 300-P Air Purifier
8.0

Levoit Core 300-P Air Purifier

Small rooms up to about 220 sq ft. Simple, quiet sleep mode, inexpensive filters. Read our Levoit Core 300 review.

$$$$Mid-range price tierImage: Levoit
Winix 5520 4-Stage WiFi True HEPA Air Purifier
8.5

Winix 5520 4-Stage WiFi True HEPA Air Purifier

AHAM Verified for 392 sq ft, True HEPA and pellet carbon for pet and cooking odors. PlasmaWave can be switched off.

$$$$Premium price tierImage: Winix
Blueair Blue Pure 311i+ Max
8.2

Blueair Blue Pure 311i+ Max

A bedroom purifier with headroom: rated for 525 sq ft so it can run quietly on low. HEPASilent, not True HEPA.

$$$$Premium price tierImage: Blueair
Blueair Blue Pure 211i Max
8.3

Blueair Blue Pure 211i Max

The most airflow in our lineup: 435 CFM smoke CADR for spaces up to about 670 sq ft.

$$$$Premium price tierImage: Blueair

For full rankings, see the best air purifiers of 2026, our Levoit Core 300 review, and more picks for your home in smart home and comfort.

Frequently asked questions

What does CADR stand for?

Clean air delivery rate. It's the volume of filtered air a purifier delivers, in cubic feet per minute, measured at its highest speed. It's rated separately for smoke, dust and pollen, and the smoke number matters most for small particles.

How do I calculate the air purifier size for my room?

Multiply length by width to get square feet, then multiply by two-thirds. That's the minimum smoke CADR AHAM recommends for an 8-foot ceiling. A 15 by 20 foot room (300 sq ft) needs about 200 CFM. For wildfire smoke, AHAM recommends a smoke CADR equal to the full square footage.

What is the difference between HEPA and True HEPA?

True HEPA usually refers to the Department of Energy definition the EPA cites: a filter that can theoretically remove at least 99.97% of particles 0.3 microns in size. Terms like HEPA-type or HEPA-style have no standard meaning, so check the stated efficiency.

Are ionizers in air purifiers safe?

The EPA advises avoiding air cleaners that intentionally produce ozone and notes that ionizers and plasma devices may emit some. Many purifiers with these features let you turn them off. Look for CARB certification, and check the manual.

Does an ENERGY STAR air purifier clean better?

No. The EPA notes that ENERGY STAR means the purifier meets energy-efficiency guidelines. It says nothing about how well it cleans the air. Compare CADR for that.

Can one air purifier clean my whole house?

Usually not. Portable purifiers are designed for a single room. The EPA suggests sizing for the whole connected space in open floor plans, or using more than one unit.